Resistance method oil system
Resistance method oil system

Solenoid operated piston pump EX

Specifications Pump Discharge Volume 0.4〜0.9ml/stroke (Adjustable) Discharge Pressure 0.4MPaMax Voltage / Current AC100Vφ1 AC200Vφ1 (50Hz/60Hz) Oil level switch (Option) Solenoid Voltage AC100V 50Hz Retention 0.5A  Start-up 5.8A 60Hz Retention 0.52A  Start-up 6.0A AC200V 50Hz Retention 0.25A  Start-up 2.9A 60Hz Retention 0.26A  Start-up 3.0A Working Viscosity Range 32〜1300mm2/S Reservoir Capacity 1.8l Weight 1.85kg How To Order Model Model Part Number EX-1 […]

Detail infor

Specifications

Pump Discharge Volume 0.4〜0.9ml/stroke (Adjustable)
Discharge Pressure 0.4MPaMax
Voltage / Current AC100Vφ1 AC200Vφ1 (50Hz/60Hz)
Oil level switch
(Option)
Solenoid Voltage AC100V 50Hz Retention 0.5A  Start-up 5.8A
60Hz Retention 0.52A  Start-up 6.0A
AC200V 50Hz Retention 0.25A  Start-up 2.9A
60Hz Retention 0.26A  Start-up 3.0A
Working Viscosity Range 32〜1300mm2/S
Reservoir Capacity 1.8l
Weight 1.85kg

How To Order

電磁駆動潤滑吐出型ピストンポンプ EX型 How to Order

Model

Model Part Number
EX-1 102703
EX-1C 102701
EX-1LC 102705
Model Part Number
EX-2 102702
EX-2C 102700
EX-2LC 102704

Directions for use

Oil viscosity varies with oil temperature. Be sure to use oil within the working viscosity range. Refer to the viscosity table.
Do not use any special additive-contained oil, water soluble oil and solvent.
Periodically check the oil in the reservoir for impurities. Replace it, if necessary, with fresh oil immediately. Be sure to clean the reservoir before oil change.
Make sure that proper voltage and pressure are proper.
Do not overtighten the discharge joint. Refer to the tightening torque table.
Do not operate the pump dry.

Oil quantity adjustment method

  1. ① reduce the coupling rod hexagonal portion, please loosen up the ③ lock nut 2 spring washer become free.

    After setting the rotation desired discharge? Amounts ④ adjustment screw in the direction indicated by the solid arrow If you want to increase the amount, fixed by the ② and ③.

    If you want to reduce the amount, after setting the desired discharge amount to rotate the ④ adjustment screw in the dotted arrow direction, it is fixed by the ② and ③.

    Adjustment screw is the adjustment amount in one rotation is 0.06ml.

油量調整方法

Document

Pump Drawing

Hydraulic circuit drawing

Wiring digram

Wiring digram

Dimensional Drawing

Dimensional drawing
warning Improper handling can result in a death or serious injury.
 
Electrical shock may be received under certain conditions Electrical shock may be received under certain conditions.。
 
Be sure to ground. Be sure to ground.