Automatic intermittent gear pump AMR-III DS
Model indication method Model Part Number AMR-ⅢDS-1 112141 AMR-ⅢDS-1-3 112143 AMR-ⅢDS-2 112142 AMR-ⅢDS-2-3 112144 Directions for use ● Do not remove the oil strainer. It may cause contamination. ● Replace or clean the suction filter once a year. Please see the adaptation table. ● Since the viscosity changes depending on the oil temperature in […]
Detail infor
Model indication method
Model | Part Number |
---|---|
AMR-ⅢDS-1 | 112141 |
AMR-ⅢDS-1-3 | 112143 |
AMR-ⅢDS-2 | 112142 |
AMR-ⅢDS-2-3 | 112144 |
Directions for use
● Do not remove the oil strainer. It may cause contamination.
● Replace or clean the suction filter once a year. Please see the adaptation table.
● Since the viscosity changes depending on the oil temperature in summer and winter, be careful to use it within the Operating viscosity range. Please see the viscosity table.
● Do not use special additive oil, water-soluble oil or solvent.
● Regularly inspect the oil in use for contamination, etc. If any are found, immediately flush the tank and replace it with new oil.
● Please be careful about mistakes such as voltage.
● Do not overtighten the outlet fitting. Please refer to the tightening torque chart.
Specifications
Pump | Discharge Volume | 150mℓ/min(50Hz)180mℓ/min(60Hz) | |
Discharge Pressure | 0.8MPa(safety valve set pressure) | ||
Motor |
Voltage / Current | AC100Vφ1/0.83A AC200Vφ1/0.41A50Hz) AC100Vφ1/0.64A AC200Vφ1/0.33A(60Hz) |
|
Output | 20W(50Hz/60Hz)Capacitor Motor | ||
Controller |
Timer | Discharge time adjustable range::1〜99sec. (2.5〜247.5mℓ)50Hz (3〜297mℓ)60Hz Interval time adjustable range::1〜9999min. 1〜9999counts ※Please specify when ordering if you want to count control. |
|
Abnormal output | Contact type A Contact (NO) | ||
Contact capacity AC250V 1.5A | |||
Emergency Detection | Oil level switch | A Contact (NO) ON at low level | |
Prerssure switch | A Contact (NO) Operating pressure: 0.14MPa ON Reset pressure : 0.07MPa OFF | ||
Liquid crystal display | INTERVAL | display ”INT” | |
DISCHARGE | display ”DIS” | ||
ALARM | When oil side decreases, display ”OILLEVEL ERR” When pressure is abnormal, display ”PRESSURE ERR” | ||
Operating viscosity range | 68〜1300mm²/s(50Hz) | ||
Reservoir Capacity | 1.8ℓ、3ℓ(plastic) 3ℓ、4ℓ、8ℓ(sheet metal) | ||
Weight | 1.8ℓReservoir:3.2kg、3ℓReservoir:4kg |
Controller setting
Pump Drawing
Wiring digram
Dimensional Drawing
Incorrect handling may result in death or damage.
Under certain conditions, there is a possibility of electric shock.
Be sure to connect the ground wire.