Automatic intermittent piston pump MMXL-III
Model indication method Specifications Pump Discharge Volume 0.2〜1.0mℓ/stroke 1.5〜2.5mℓ/stroke 2.5〜5.5mℓ/stroke Discharge Pressure 0.3MPa Motor Voltage / Current AC100Vφ1/50mA AC200Vφ1/25mA(50Hz) AC100Vφ1/42mA AC200Vφ1/18mA(60Hz) Output 3W Synchronous Motor Emergency Detection Oil Level Switch Contact Type A Contact (NO) ON at low level Contact capacity 0.5A,AC DC200V/30W smaller Operation Rating Continuous Working Viscosity Range 32〜1300mm²/s Reservoir Capacity 1.8ℓ、3ℓ(plastic) 3ℓ、4ℓ、8ℓ(sheet metal) Weight 1.8ℓwith […]
Detail infor
Model indication method

Specifications
| Pump | Discharge Volume | 0.2〜1.0mℓ/stroke |
| 1.5〜2.5mℓ/stroke | ||
| 2.5〜5.5mℓ/stroke | ||
| Discharge Pressure | 0.3MPa | |
| Motor | Voltage / Current | AC100Vφ1/50mA |
| AC200Vφ1/25mA(50Hz) | ||
| AC100Vφ1/42mA | ||
| AC200Vφ1/18mA(60Hz) | ||
| Output | 3W Synchronous Motor | |
| Emergency Detection | Oil Level Switch | Contact Type A Contact (NO) ON at low level Contact capacity 0.5A,AC DC200V/30W smaller |
| Operation Rating | Continuous | |
| Working Viscosity Range | 32〜1300mm²/s | |
| Reservoir Capacity | 1.8ℓ、3ℓ(plastic) 3ℓ、4ℓ、8ℓ(sheet metal) |
|
| Weight | 1.8ℓwith Reservoirs1.8kg | |
| Protection class | IP54(CE Approved type) | |
| Part Number | Part Number | Part Number | Part Number | |
|---|---|---|---|---|
| MMXL-ⅢCE-1A-1 | 367001 | MMXL-ⅢCE-2D-1 | 367022 | |
| MMXL-ⅢCE-1A-1L | 367055 | MMXL-ⅢCE-2D-1L | 367076 | |
| MMXL-ⅢCE-1A-2 | 367007 | MMXL-ⅢCE-2D-2 | 367028 | |
| MMXL-ⅢCE-1A-2L | 367061 | MMXL-ⅢCE-2D-2L | 367082 | |
| MMXL-ⅢCE-1B-1 | 367002 | MMXL-ⅢCE-2E-1 | 367023 | |
| MMXL-ⅢCE-1B-1L | 367056 | MMXL-ⅢCE-2E-1L | 367077 | |
| MMXL-ⅢCE-1B-2 | 367008 | MMXL-ⅢCE-2E-2 | 367029 | |
| MMXL-ⅢCE-1B-2L | 367062 | MMXL-ⅢCE-2E-2L | 367083 | |
| MMXL-ⅢCE-1C-1 | 367003 | MMXL-ⅢCE-2F-1 | 367024 | |
| MMXL-ⅢCE-1C-1L | 367057 | MMXL-ⅢCE-2F-1L | 367078 | |
| MMXL-ⅢCE-1C-2 | 367009 | MMXL-ⅢCE-2F-2 | 367030 | |
| MMXL-ⅢCE-1C-2L | 367063 | MMXL-ⅢCE-2F-2L | 367084 | |
| MMXL-ⅢCE-1D-1 | 367004 | MMXL-ⅢCE-5A-1 | 367037 | |
| MMXL-ⅢCE-1D-1L | 367058 | MMXL-ⅢCE-5A-1L | 367091 | |
| MMXL-ⅢCE-1D-2 | 367010 | MMXL-ⅢCE-5A-2 | 367043 | |
| MMXL-ⅢCE-1D-2L | 367064 | MMXL-ⅢCE-5A-2L | 367097 | |
| MMXL-ⅢCE-1E-1 | 367005 | MMXL-ⅢCE-5B-1 | 367038 | |
| MMXL-ⅢCE-1E-1L | 367059 | MMXL-ⅢCE-5B-1L | 367092 | |
| MMXL-ⅢCE-1E-2 | 367011 | MMXL-ⅢCE-5B-2 | 367044 | |
| MMXL-ⅢCE-1E-2L | 367065 | MMXL-ⅢCE-5B-2L | 367098 | |
| MMXL-ⅢCE-1F-1 | 367006 | MMXL-ⅢCE-5C-1 | 367039 | |
| MMXL-ⅢCE-1F-1L | 367060 | MMXL-ⅢCE-5C-1L | 367093 | |
| MMXL-ⅢCE-1F-2 | 367012 | MMXL-ⅢCE-5C-2 | 367045 | |
| MMXL-ⅢCE-1F-2L | 367066 | MMXL-ⅢCE-5C-2L | 367099 | |
| MMXL-ⅢCE-2A-1 | 367019 | MMXL-ⅢCE-5D-1 | 367040 | |
| MMXL-ⅢCE-2A-1L | 367073 | MMXL-ⅢCE-5D-1L | 367094 | |
| MMXL-ⅢCE-2A-2 | 367025 | MMXL-ⅢCE-5D-2 | 367046 | |
| MMXL-ⅢCE-2A-2L | 367079 | MMXL-ⅢCE-5D-2L | 367100 | |
| MMXL-ⅢCE-2B-1 | 367020 | MMXL-ⅢCE-5E-1 | 367041 | |
| MMXL-ⅢCE-2B-1L | 367074 | MMXL-ⅢCE-5E-1L | 367095 | |
| MMXL-ⅢCE-2B-2 | 367026 | MMXL-ⅢCE-5E-2 | 367047 | |
| MMXL-ⅢCE-2B-2L | 367080 | MMXL-ⅢCE-5E-2L | 367101 | |
| MMXL-ⅢCE-2C-1 | 367021 | MMXL-ⅢCE-5F-1 | 367042 | |
| MMXL-ⅢCE-2C-1L | 367075 | MMXL-ⅢCE-5F-1L | 367096 | |
| MMXL-ⅢCE-2C-2 | 367027 | MMXL-ⅢCE-5F-2 | 367048 | |
| MMXL-ⅢCE-2C-2L | 367081 | MMXL-ⅢCE-5F-2L | 367102 |
Dimensional Drawing

Directions for use
● Do not remove the oil strainer. It may cause contamination.
● Replace or clean the suction filter once a year.
Please see the adaptation table.
● Since oil changes its viscosity depending on the oil temperature in summer and winter, be careful to use it within the Working Viscosity Range. Please see the viscosity table.
● Do not use special additive oil, water-soluble oil or solvent.
● Regularly inspect the oil in use for contamination, etc. If any are found, immediately flush the tank and replace it with new oil.
● Please be careful about mistakes such as voltage.
● Do not overtighten the outlet fitting. Please refer to the tightening torque chart.
● Do not forcibly depress the oil level adjustment knob.
● Do not adjust the oil level when the oil level adjustment knob is raised. Please adjust at the lowest limit.
![]()
Improper handling can result in a death or serious injury.
![]()
Electrical shock may be received under certain conditions。
![]()
Be sure to ground.
Replacement Motor Model
| Interval3分6分15分30分60分120分 | ||||||||
| Motor speed rpm (50 Hz) | 20 | 10 | 4 | 2 | 1 | 1/2 | ||
| Replacement Motor Model | 100V | Part Number | M-A1 | M-B1 | M-C1 | M-D1 | M-E1 | M-F1 |
| Part Number | 521210 | 521194 | 521193 | 520062 | 520061 | 520060 | ||
| 200V | Part Number | M-A2 | M-B2 | M-C2 | M-D2 | M-E2 | M-F2 | |
| Part Number | 521328 | 521196 | 521195 | 520067 | 520066 | 520065 | ||
Dimensional Drawing

Wiring digram

How to adjust the Discharge Volume

※ If you adjust the oil amount, the balance of the oil amount at each lubrication point will change, so be sure to check with the machine manufacturer.