Resistance method oil system
Resistance method oil system

Automatic intermittent piston pump MMXL-III

Model indication method Specifications Pump Discharge Volume 0.2〜1.0mℓ/stroke 1.5〜2.5mℓ/stroke 2.5〜5.5mℓ/stroke Discharge Pressure 0.3MPa Motor Voltage / Current AC100Vφ1/50mA AC200Vφ1/25mA(50Hz) AC100Vφ1/42mA AC200Vφ1/18mA(60Hz) Output 3W Synchronous Motor Emergency Detection Oil Level Switch Contact Type A Contact (NO) ON at low level  Contact capacity 0.5A,AC DC200V/30W smaller Operation Rating Continuous Working Viscosity Range 32〜1300mm²/s Reservoir Capacity 1.8ℓ、3ℓ(plastic)  3ℓ、4ℓ、8ℓ(sheet metal) Weight 1.8ℓwith […]

Detail infor

Model indication method

Automatic intermittent piston pump MMXL-III


 Model indication method

Specifications

Pump Discharge Volume 0.2〜1.0mℓ/stroke
1.5〜2.5mℓ/stroke
2.5〜5.5mℓ/stroke
Discharge Pressure 0.3MPa
Motor Voltage / Current AC100Vφ1/50mA
AC200Vφ1/25mA(50Hz)
AC100Vφ1/42mA
AC200Vφ1/18mA(60Hz)
Output 3W Synchronous Motor
Emergency Detection Oil Level Switch Contact Type A Contact (NO) ON at low level 
Contact capacity 0.5A,AC
DC200V/30W smaller
Operation Rating Continuous
Working Viscosity Range 32〜1300mm²/s
Reservoir Capacity 1.8ℓ、3ℓ(plastic) 
3ℓ、4ℓ、8ℓ(sheet metal)
Weight 1.8ℓwith Reservoirs1.8kg
Protection class IP54(CE Approved type)

 

Part Number Part Number   Part Number Part Number
MMXL-ⅢCE-1A-1 367001   MMXL-ⅢCE-2D-1 367022
MMXL-ⅢCE-1A-1L 367055   MMXL-ⅢCE-2D-1L 367076
MMXL-ⅢCE-1A-2 367007   MMXL-ⅢCE-2D-2 367028
MMXL-ⅢCE-1A-2L 367061   MMXL-ⅢCE-2D-2L 367082
MMXL-ⅢCE-1B-1 367002   MMXL-ⅢCE-2E-1 367023
MMXL-ⅢCE-1B-1L 367056   MMXL-ⅢCE-2E-1L 367077
MMXL-ⅢCE-1B-2 367008   MMXL-ⅢCE-2E-2 367029
MMXL-ⅢCE-1B-2L 367062   MMXL-ⅢCE-2E-2L 367083
MMXL-ⅢCE-1C-1 367003   MMXL-ⅢCE-2F-1 367024
MMXL-ⅢCE-1C-1L 367057   MMXL-ⅢCE-2F-1L 367078
MMXL-ⅢCE-1C-2 367009   MMXL-ⅢCE-2F-2 367030
MMXL-ⅢCE-1C-2L 367063   MMXL-ⅢCE-2F-2L 367084
MMXL-ⅢCE-1D-1 367004   MMXL-ⅢCE-5A-1 367037
MMXL-ⅢCE-1D-1L 367058   MMXL-ⅢCE-5A-1L 367091
MMXL-ⅢCE-1D-2 367010   MMXL-ⅢCE-5A-2 367043
MMXL-ⅢCE-1D-2L 367064   MMXL-ⅢCE-5A-2L 367097
MMXL-ⅢCE-1E-1 367005   MMXL-ⅢCE-5B-1 367038
MMXL-ⅢCE-1E-1L 367059   MMXL-ⅢCE-5B-1L 367092
MMXL-ⅢCE-1E-2 367011   MMXL-ⅢCE-5B-2 367044
MMXL-ⅢCE-1E-2L 367065   MMXL-ⅢCE-5B-2L 367098
MMXL-ⅢCE-1F-1 367006   MMXL-ⅢCE-5C-1 367039
MMXL-ⅢCE-1F-1L 367060   MMXL-ⅢCE-5C-1L 367093
MMXL-ⅢCE-1F-2 367012   MMXL-ⅢCE-5C-2 367045
MMXL-ⅢCE-1F-2L 367066   MMXL-ⅢCE-5C-2L 367099
MMXL-ⅢCE-2A-1 367019   MMXL-ⅢCE-5D-1 367040
MMXL-ⅢCE-2A-1L 367073   MMXL-ⅢCE-5D-1L 367094
MMXL-ⅢCE-2A-2 367025   MMXL-ⅢCE-5D-2 367046
MMXL-ⅢCE-2A-2L 367079   MMXL-ⅢCE-5D-2L 367100
MMXL-ⅢCE-2B-1 367020   MMXL-ⅢCE-5E-1 367041
MMXL-ⅢCE-2B-1L 367074   MMXL-ⅢCE-5E-1L 367095
MMXL-ⅢCE-2B-2 367026   MMXL-ⅢCE-5E-2 367047
MMXL-ⅢCE-2B-2L 367080   MMXL-ⅢCE-5E-2L 367101
MMXL-ⅢCE-2C-1 367021   MMXL-ⅢCE-5F-1 367042
MMXL-ⅢCE-2C-1L 367075   MMXL-ⅢCE-5F-1L 367096
MMXL-ⅢCE-2C-2 367027   MMXL-ⅢCE-5F-2 367048
MMXL-ⅢCE-2C-2L 367081   MMXL-ⅢCE-5F-2L 367102

Dimensional Drawing

Automatic intermittent piston pump MMXL-IIIDimensional Drawing

Directions for use

● Do not remove the oil strainer. It may cause contamination.
● Replace or clean the suction filter once a year.
Please see the adaptation table.
● Since oil changes its viscosity depending on the oil temperature in summer and winter, be careful to use it within the Working Viscosity Range. Please see the viscosity table.
● Do not use special additive oil, water-soluble oil or solvent.
● Regularly inspect the oil in use for contamination, etc. If any are found, immediately flush the tank and replace it with new oil.
● Please be careful about mistakes such as voltage.
● Do not overtighten the outlet fitting. Please refer to the tightening torque chart.
● Do not forcibly depress the oil level adjustment knob.
● Do not adjust the oil level when the oil level adjustment knob is raised. Please adjust at the lowest limit.

Warning
Improper handling can result in a death or serious injury.

Electric shock
Electrical shock may be received under certain conditions。

electrical ground
Be sure to ground.

Replacement Motor Model

Interval3分6分15分30分60分120分
Motor speed rpm (50 Hz) 20 10 4 2 1 1/2
Replacement Motor Model 100V Part Number M-A1 M-B1 M-C1 M-D1 M-E1 M-F1
Part Number 521210 521194 521193 520062 520061 520060
200V Part Number M-A2 M-B2 M-C2 M-D2 M-E2 M-F2
Part Number 521328 521196 521195 520067 520066 520065

 

Dimensional Drawing

Automatic intermittent piston pump MMXL-III
Pump回路図

 

Wiring digram

Automatic intermittent piston pump MMXL-III
Wiring digram

How to adjust the Discharge Volume

Automatic intermittent piston pump MMXL-III
How to adjust the Discharge Volume

 

※ If you adjust the oil amount, the balance of the oil amount at each lubrication point will change, so be sure to check with the machine manufacturer.