Automatic intermittent gear pump AMO-III DS
Model indication method Model Part Number AMO-III DS-1 285301 AMO-III DS-1-3 285303 AMO-III DS-2 285302 AMO-III DS-2-3 285304 低粘度Specifications Model Part Number Voltage Tank Operating viscosity range 1 AMO-IIIDSL-1 285331 100V 1.8ℓ 10 ~ 800mm2/S 2 AMO-IIIDSL-2 285332 200V 1.8ℓ 10 ~ 800mm2/S 3 AMO-IIIDSL-2 285333 100V 3ℓ 10 ~ 800mm2/S 4 AMO-IIIDSL-2 285334 200V 3ℓ 10 ~ 800mm2/S Directions for […]
Detail infor
Model indication method
Model | Part Number |
---|---|
AMO-III DS-1 | 285301 |
AMO-III DS-1-3 | 285303 |
AMO-III DS-2 | 285302 |
AMO-III DS-2-3 | 285304 |
低粘度Specifications
Model | Part Number | Voltage | Tank | Operating viscosity range | |
---|---|---|---|---|---|
1 | AMO-IIIDSL-1 | 285331 | 100V | 1.8ℓ | 10 ~ 800mm2/S |
2 | AMO-IIIDSL-2 | 285332 | 200V | 1.8ℓ | 10 ~ 800mm2/S |
3 | AMO-IIIDSL-2 | 285333 | 100V | 3ℓ | 10 ~ 800mm2/S |
4 | AMO-IIIDSL-2 | 285334 | 200V | 3ℓ | 10 ~ 800mm2/S |
Directions for use
● Do not remove the oil strainer. It may cause contamination.
● Replace or clean the suction filter once a year.
● Since the viscosity changes depending on the oil temperature in summer and winter, be careful to use it within the Operating viscosity range. Please see the viscosity table.
● Do not use special additive oil, water-soluble oil or solvent.
● Regularly inspect the oil in use for contamination, etc. If any are found, immediately flush the tank and replace it with new oil.
● Please be careful about mistakes such as Voltage.
● Do not overtighten the outlet fitting. Please refer to the tightening torque chart.
● Low viscosity Specifications are also available, so please contact our Global Center.
Specifications
Pump | Discharge Volume | 150mℓ/min(50Hz) 180mℓ/min(60Hz) | |
Discharge Pressure | 2.0MPa(safety valve set pressure) | ||
Motor |
Voltage / Current | AC100Vφ1/0.83A | |
AC200Vφ1/0.41A(50Hz) | |||
AC100Vφ1/0.64A | |||
AC200Vφ1/0.33A(60Hz) | |||
Output | 20W(50Hz/60Hz)Capacitor Motor | ||
Controller |
Timer | TimerDischarge time adjustable range:: | 1〜99sec. |
Interval time adjustable range:: | 1〜9999min. | ||
1〜9999counts | |||
※Please specify when ordering if you want to count control. | |||
Abnormal output | Contact type | A Contact (NO) | |
Contact capacity | AC250V 1.5A | ||
Emergency Detection | Oil level pressure Oil level switch |
A Contact (NO) ON at low level | |
Prerssure switch | BContact (NC) Operating pressure:1.7MPa OFF Reset pressure: 0.9MPa ON |
||
Liquid crystal display | INTERVAL | display ”INT” | |
DISCHARGE | display ”DIS” | ||
ALARM |
When oil side decreases, display ”OILLEVEL ERR” When pressure is abnormal, display ”PRESSURE ERR” |
||
Operating viscosity range | 68〜1800mm²/s(50Hz) | ||
Reservoir Capacity | 1.8ℓ、3ℓ(plastic) 3ℓ、4ℓ、8ℓ(sheet metal) | ||
Weight | 1.8ℓReservoir:3.2kg、3ℓReservoir:4kg |
Controller setting
Pump Drawing
Wiring digram
Dimensional Drawing
Incorrect handling may result in death or damage.
Under certain conditions, there is a possibility of electric shock.
Be sure to connect the ground wire.