Quantitative method
Quantitative method

Automatic intermittent gear pump AMO-III DS

Model indication method Model Part Number AMO-III DS-1 285301 AMO-III DS-1-3 285303 AMO-III DS-2 285302 AMO-III DS-2-3 285304 低粘度Specifications   Model Part Number Voltage Tank Operating viscosity range 1 AMO-IIIDSL-1 285331 100V 1.8ℓ 10 ~ 800mm2/S 2 AMO-IIIDSL-2 285332 200V 1.8ℓ 10 ~ 800mm2/S 3 AMO-IIIDSL-2 285333 100V 3ℓ 10 ~ 800mm2/S 4 AMO-IIIDSL-2 285334 200V 3ℓ 10 ~ 800mm2/S   Directions for […]

Detail infor

Model indication method

MO2 · MO2C Type (Direct pressure operated metering valve)
 Model Display method

Model Part Number
AMO-III DS-1 285301
AMO-III DS-1-3 285303
AMO-III DS-2 285302
AMO-III DS-2-3 285304

低粘度Specifications

  Model Part Number Voltage Tank Operating viscosity range
1 AMO-IIIDSL-1 285331 100V 1.8ℓ 10 ~ 800mm2/S
2 AMO-IIIDSL-2 285332 200V 1.8ℓ 10 ~ 800mm2/S
3 AMO-IIIDSL-2 285333 100V 3ℓ 10 ~ 800mm2/S
4 AMO-IIIDSL-2 285334 200V 3ℓ 10 ~ 800mm2/S

 

Directions for use

● Do not remove the oil strainer. It may cause contamination.

● Replace or clean the suction filter once a year.

● Since the viscosity changes depending on the oil temperature in summer and winter, be careful to use it within the Operating viscosity range. Please see the viscosity table.

● Do not use special additive oil, water-soluble oil or solvent.

● Regularly inspect the oil in use for contamination, etc. If any are found, immediately flush the tank and replace it with new oil.

● Please be careful about mistakes such as Voltage.

● Do not overtighten the outlet fitting. Please refer to the tightening torque chart.

● Low viscosity Specifications are also available, so please contact our Global Center.

Specifications

Pump Discharge Volume 150mℓ/min(50Hz) 180mℓ/min(60Hz)
Discharge Pressure 2.0MPa(safety valve set pressure)

 

Motor

Voltage / Current AC100Vφ1/0.83A 
AC200Vφ1/0.41A(50Hz)
AC100Vφ1/0.64A 
AC200Vφ1/0.33A(60Hz)
Output 20W(50Hz/60Hz)Capacitor Motor

 

 

 

 

Controller

Timer TimerDischarge time adjustable range:: 1〜99sec.
Interval time adjustable range:: 1〜9999min.
  1〜9999counts
※Please specify when ordering if you want to count control.
Abnormal output Contact type     A Contact (NO)
Contact capacity    AC250V 1.5A
Emergency Detection Oil level pressure
Oil level switch
A Contact (NO) ON at low level
Prerssure switch BContact (NC)
Operating pressure:1.7MPa OFF
Reset pressure: 0.9MPa ON
Liquid crystal display INTERVAL display ”INT”
DISCHARGE display ”DIS”
ALARM

When oil side decreases, display ”OILLEVEL ERR” When pressure is abnormal, display ”PRESSURE ERR”

Operating viscosity range 68〜1800mm²/s(50Hz)
Reservoir Capacity 1.8ℓ、3ℓ(plastic) 3ℓ、4ℓ、8ℓ(sheet metal)
Weight 1.8ℓReservoir:3.2kg、3ℓReservoir:4kg

Controller setting

MO2 · MO2C Type (Direct pressure operated metering valve)
 Controller Setting

Pump Drawing

MO2 · MO2C Type (Direct pressure operated metering valve)

Wiring digram

MO2 · MO2C Type (Direct pressure operated metering valve)
 Wiring digram

Dimensional Drawing

MO2 · MO2C Type (Direct pressure operated metering valve)
 Dimensional Drawing

Warning
Incorrect handling may result in death or damage.

Electric shock
Under certain conditions, there is a possibility of electric shock.

electrical ground
Be sure to connect the ground wire.