Automatic intermittent gear pump AMO-II-150S

Specifications Pump Discharge Volume 150ml/min (50Hz) 180ml/min (60Hz) Discharge Pressure 2.0MPa (safety valve set pressure) Motor Voltage / Current AC100Vφ1/0.83A AC200Vφ1/0.41A (50Hz) AC100Vφ1/0.64A AC200Vφ1/0.33A (60Hz) Output 20W (50Hz/60Hz) CondesorMotor Emergency Detection Oil level pressure Oil level switch Contact Type  A Contact (NO) ON at low level Contact capacity  0.5A AC DC200V/30W smaller Prerssure switch Contact Type  A Contact (NO) […]

Detail infor

Specifications

Pump Discharge Volume 150ml/min (50Hz) 180ml/min (60Hz)
Discharge Pressure 2.0MPa (safety valve set pressure)
Motor Voltage / Current AC100Vφ1/0.83A AC200Vφ1/0.41A (50Hz)
AC100Vφ1/0.64A AC200Vφ1/0.33A (60Hz)
Output 20W (50Hz/60Hz) CondesorMotor
Emergency Detection Oil level pressure
Oil level switch
Contact Type  A Contact (NO) ON at low level
Contact capacity  0.5A AC DC200V/30W smaller
Prerssure switch
Contact Type  A Contact (NO)
Operating pressure:1.7MPa OFF
Reset pressure: 0.9MPa ON
Contact capacity AC DC250V/3A
Operation Rating Max. Discharge time:99sec
Min. Interval time:1min
Working Viscosity Range 68〜1000mm2/S (50Hz)
Reservoir Capacity 1.8ℓ、3ℓ (plastic) 3ℓ、4ℓ、8ℓ (sheet metal)
Weight 1.8ℓReservoir:3.3kg 3ℓReservoir:4kg(plastic)

How To Order

Automatic intermittent gear pump AMO-II-150S型 How to Order
 

Model

Model Part Number
AMO-II-150S-1 202067
AMO-II-150S-1-3 202069
AMO-II-150S-1-P 202071
AMO-II-150S-1-P-3 202073
Model Part Number
AMO-II-150S-2 202068
AMO-II-150S-2-3 202070
AMO-II-150S-2-P 202072
AMO-II-150S-2-P-3 202074

Directions for use

This pump unit requires a separate control circuit to operate.
Do not remove the oil strainer to keep the pump clear of foreign matter.
Replace or clean the suction filter at least once a year. Click here to view the service list.
Oil viscosity varies with oil temperature. Be sure to use oil within the working viscosity range. Refer to the viscosity table.
Do not use any special additive-contained oil, water soluble oil and solvent.
Periodically check the oil in the reservoir for impurities. Replace it, if necessary, with fresh oil immediately. Be sure to clean the reservoir before oil change.
Make sure that proper voltage and pressure are proper.
Do not overtighten the discharge joint. Refer to the tightening torque table.
Low-oil viscosity versions are available. Contact us for information.
For system planning information, Contact us.
 

Document

Pump Drawing

Hydraulic circuit drawing

Wiring digram

Wiring digram

Dimensional Drawing

Dimensional drawing
warning Improper handling can result in a death or serious injury.
 
Electrical shock may be received under certain conditions Electrical shock may be received under certain conditions.。
 
Be sure to ground. Be sure to ground.