LHL grease lubrication system
LHL grease lubrication system

Grease pump EGM II

Specifications Power DC24V Power Consumption 45.6W Discharge pressure 8MPa (Only for LHL System)   10MPa Maximum discharging time Below 7m 30s Interval time 3 times discharging time Wiring method Terminal connection Manual override switch With(Optional: Only PDI system) ※1 Grease level switch With Solenoid cover Non combustible plastic( UL94-V0) IPRated IP54 CE approval Yes Pump […]

Detail infor

Specifications

Power DC24V
Power Consumption 45.6W
Discharge pressure 8MPa (Only for LHL System)
  10MPa
Maximum discharging time Below 7m 30s
Interval time 3 times discharging time
Wiring method Terminal connection
Manual override switch With(Optional: Only PDI system) ※1
Grease level switch With
Solenoid cover Non combustible plastic( UL94-V0)
IPRated IP54
CE approval Yes
Pump air bleeding With restriction
Weight 2.0kg(Manual override switch有:2.1kg)
※Although the Manual Override Switch provides a dry contact to activate the pump, its capacity is not sufficient to sustain the power required to operate the pump. Therefore, the power needs to be provided directly to the pump from the machine control panel.

How To Order

Model Display method

Model

Model Part Number
EGM2-10S-4-7CL 103937
EGM2-10S-4-7CLEB 103938
EGM2-10T-4-7CL 103947
EGM2-8S-4-7CLFB-LHL 103936
EGM2-8S-4-7CL-LHL 103935

Environmental conditions

Use recommended cartridge greases.
Never use molybdenum disulfide-contained grease.
When using grease which is not Lube original grease, please be sure to consult.
Do not use any greases containing substances that attack brass and rubber.
When replacing cartridge, take care not to let foreign matter in the .
Avoid continuous operation.
After changing the cartridge, bleed the air inside the pump by opening the air bleeding valve.

Document

Hydraulic circuit drawing
Pump circuit diagram
Wiring digram
Wiring digram
Dimensional drawing

Grease level switch

Grease level switch